BLDC DIA 95 MOTOR

BLDC φ 95 motor is specially designed for Air conditioner (Outdoor Unit),Desert Cooler, Blower and General Purpose with ~ 50 % less power consumption as compared to Induction motors. The motor is of insulation class B

BLDC motors have additional features like constant RPM, Remote capability option, current based trip, over/ under voltage protection, 3 trials for auto restart before shut down. Auto power down for locked rotor and many other features. These can be used as general purpose motors in the range of max. Power specified.

MICROElectronically CommutatedController 1,2,3,4Stack Diameter in mmBearing Type (S-Sleeve, B-Ball Bearing)Stack Length in mmRotation (A-Antilock, C-Clock)Voltage (115-1, 230V-2, 12V-3,24V-4, 48V-5, 96V-6, 310V-9)A-AC, D-DCConnection Type (Terminal-T, Lead Wire-L)Internal Code
MECXXXXXXX/ XXXXXXX
  • Switch/Remote Adjustable Speed Control
  • Thermal Protection
  • Soft Start for Reducing Inrush Current
  • Interchangeable use of Remote and Switches
  • Last Speed Saved
  • Last Information Saved During Power Failure for Speed, Pump and Swing
  • Auto Turn ON when Power Resumed

Mechanical Dimensions

MODEL NO. A B C D E F G H I J K L M N
MEC195B25C2/AL-SJ7
Φ 5.0
127 97.5 - 82 159.5 78 37.5 41 6.9 M6, L.H. 11 8 120
MEC195B30A/2AL-SK1 Φ 5.0
127 97.5 - 82 159.5 78 37.5 41 6.9 M6, L.H.
11 8 120
MEC195B30A/5DL-SK2 Φ 5.0
127
97.5 95 82 272 190 56 44 11.5 - -- 12.7 --
  • Desert Cooler
  • Room Cooler
  • Personal Cooler
  • Blowers
  • General Purpose
  • Operating Voltage : 150V ≤ Vin ≤ 265V
  • Motor Trip Voltage : <160 , >270 V
  • Over Load Trip Current : Factory Set
  • RPM vs Voltage : Constant RPM
  • Time Delay to Start : ≤ 5 Sec.
  • Delays : Remote Sensing Start Delay and Full Speed are Achieved in Factory Set Delays
  • Operating Temp. : -10°C to +55°C
  • Humidity : ≤ 95%RH@50°C

Safety Parameters

  • Class-B Insulation
  • Insulation Resistance > 10MΩ@500V DC
  • HVAC : 1500VAC, <5mA

Remote Features

  • ON/OFF Switch
  • Pump ON/OFF
  • Swing ON/OFF
  • LED Signals for Speeds, Pump, Swing

Protections

  • Auto Power down for Locked Rotor
  • Current Based Trip : Factory Set
  • Over/Under Voltage Protection
  • 3 Trials of Auto Restart before Shut Down
  • HVAC : 1500VAC, <5mA

Electrical Performance

Controller-MCON003
MODEL NOFAN SIZES
OPERATING VOLTAGE/ FREQ.RPM
OUTPUT POWER
INPUT CURRENT
INPUT POWER
CONSTANT RPM (VOLTAGE RANGE)
EFF
MEC195B25C/2AL-SJ717.5'', 3 BLADE/ 20'' O.D.U.230/50
900
54
0.57
74180V - 270V
73%
MEC195B30A/2AL-SK118'',3 BLADE/ 26'' O.D.U.
230/50
850
80
0.85
113190V - 270V
71%
20'',3 BLADE/O.D.U.
230/50
700
65
0.69
89
180V - 270V
73%
MEC195B30A/2AL-SK21.5 Ton W.A.C.
230/50
920
94
1.07
138210V - 270V
68%
880
80
0.90
115200V - 270V
70%
840
70
0.77
99
190V - 270V
70%