DC/AC AXIAL FAN
DC /AC Axial Fan specially designed for Instrument Cooling and General Purpose.
DC/AC Axial Fan have additional features reinforced plastic impeller and housing mounting position independent ,impedance protected ,reverse air flow ,dual voltage fans (115/230 VAC) and many other features.
DC FANS
D | |||||||||
XXX | Diameter of housing in mm | ||||||||
X | Housing width in cm | ||||||||
X |
| ||||||||
X |
| ||||||||
X |
| ||||||||
-X |
| ||||||||
X |
|
AC FANS
1203 | |||||||
X |
| ||||||
X |
| ||||||
X |
| ||||||
-X |
| ||||||
X |
|
DC FANS
- Reinforced Plastic Impeller and Housing
- Air output over struts
- Long, maintenance free life
- Mouting position independent
- Dyanamic balanced to 0.4 gm-mm
- Electronically Commutated Brushless DC Motor
- Reverse voltage polarity protection in DC
- Low power consumption
- Lead wire - SWG 24, 150mm
AC FANS
AC 120 x 120 x 39 - AXIAL FAN
- Reinforced Plastic Impeller and Metal Housing
- Air inputs over struts
- CW rotation viewed from impeller side
- Long, maintenance free life
- Mounting position independent
- Low winding temperature rise
- 70 to 95 CFM Airflow
- Impedance protected
- 230/115V AC, 1 phase, 50/60 Hz.
OPTIONS:
- Ball or sleeve Bearing
- Reverse Airflow
- Dual voltage fans : 115/230V AC
- Low voltage fans
QUALITY ASSURANCE:
- Inline inspection, testing and recording
- 100% Final testing
- 100% pre shipment Burn-In

- Instrument cooling
- Nuclear Power Site
Dimensions | Airflow CFM (Ltrs/Sec) +5% | Statis Pr. mm H,O + 10% | Noise dBA (Nominal) | Bearing S Sleeve B Ball | Speed RPM + 5% | Temperature Range °C | Current mA max. | Power W max. | Voltage V | Part No. |
---|---|---|---|---|---|---|---|---|---|---|
FANS 12V DC | ||||||||||
80x80x25 | 35 (16.5) | 5.0 | 38 | B | 3300 | -10..+80 | 220 | 2.6 | 8-16 | D802HB-2 |
25 (12.0) | 2.6 | 30 | B | 2400 | -10..+80 | 130 | 1.6 | 8-16 | D802LB-2 | |
92x92x32 | 46 (22.0) | 6.4 | 42 | B | 3300 | -10..+80 | 220 | 2.6 | 8-16 | D903HB-2 |
36 (17.0) | 4.0 | 33 | B | 2500 | -10..+80 | 130 | 1.6 | 8-16 | D-903LB-2 | |
120x120x38 | 104 (49.0) | 9.0 | 48 | B | 2800 | -10..+80 | 420 | 5.0 | 8-16 | D1204HB-2 |
85 (40.0) | 6.8 | 43 | B | 2300 | -10..+80 | 280 | 3.5 | 8-16 | D1204LB-2 | |
FANS 24V D | ||||||||||
80x80x25 | 35 (16.5) | 5.0 | 38 | B | 3300 | -10..+80 | 110 | 2.6 | 18-30 | D802HB-3 |
25 (12.0) | 2.6 | 30 | B | 2400 | -10..+80 | 65 | 1.6 | 18-30 | D802LB-3 | |
92x92x32 | 46 (22.0) | 6.4 | 42 | B | 3300 | -10..+80 | 110 | 2.6 | 18-30 | D903HB-3 |
36 (17.0) | 4.0 | 33 | B | 2500 | -10..+80 | 65 | 1.6 | 18-30 | D-903LB-3 | |
120x120x38 | 104 (49.0) | 9.0 | 48 | B | 2800 | -10..+80 | 210 | 5.0 | 18-30 | D1204HB-3 |
85 (40.0) | 6.8 | 43 | B | 2300 | -10..+80 | 140 | 3.5 | 18-30 | D1204LB-3 | |
FANS 24V DC | ||||||||||
80x80x25 | 35 (16.5) | 5.0 | 38 | B | 3300 | -10..+80 | 63 | 3.0 | 38-58 | D802HB-4 |
25 (12.0) | 2.6 | 30 | B | 2400 | -10..+80 | 37 | 1.8 | 38-58 | D802LB-4 | |
92x92x32 | 46 (22.0) | 6.4 | 42 | B | 3300 | -10..+80 | 63 | 3.0 | 38-58 | D903HB-4 |
36 (17.0) | 4.0 | 33 | B | 2500 | -10..+80 | 37 | 1.8 | 38-58 | D-903LB-4 | |
120x120x38 | 104 (49.0) | 9.0 | 48 | B | 2800 | -10..+80 | 115 | 5.5 | 38-58 | D1204HB-4 |
85 (40.0) | 6.8 | 43 | B | 2300 | -10..+80 | 80 | 3.8 | 38-58 | D1204LB-4 | |
230VAC/50Hz FANS (May also be operated at 60 Hz.) | ||||||||||
120x120x38 | 95 (44) | 9.0 | 45 | B | 2650 | -30..+70 | 160 | 18 | 230/50Hz | 1203HB-2 |
80 (38) | 6.8 | 39 | B | 2150 | -30..+70 | 130 | 15 | 230/50Hz | 1203MB-2 | |
100 (45) | 9.0 | 46 | B | 2800 | -30..+70 | -- | -- | 115-230/50-60Hz | 1203MB-3 |
Technical Datasheet | Download |